      molbox RFM Gas Flow Calibrator Kits
      型 號(hào):5141
      品 牌:美國(guó)FLUKE
      技術(shù)指標(biāo):Maximum working measurement line pressure  600 kPa (87 psi) absolute
      遵義molbox RFM Gas Flow Calibrator Kits-5141-美國(guó)FLUKE

      High end gas flow calibration made simple

      Fluke Calibration 5141, 5142 and 5144 molbox RFM gas flow calibrator kits feature molbox RFM and molbloc-L configurations optimized to cover a very wide workload combined with molstic-L and other interconnect hardware needed for a complete calibration system. Simply supply 90 psi of pure N2 or air to the system. An included regulator delivers a stable regulated flow to the molbloc. Downstream of the molbloc, an included metering valve allows you to regulate the mass flow value required for the DUT. It’s that simple; supply 90 psi gas upstream, tare the reading, and adjust the fine metering valve to deliver the desired mass flow rate with an accuracy of ± 0.5 % of reading. Fluke Calibration gas flow calibrator kits eliminate complication, but don’t compromise molbox/molbloc best in class performance.

      ·          Flow ranges cover from 1 sccm to 50 slm

      ·         ± 0.5 % of reading total one-year accuracy

      ·         Measures mass and volume flow with user settable reference pressure and temperature conditions

      ·         Reference standard is upstream of the device under test, eliminating cross contamination and expensive damage to the flow elements

      ·         Integrated gas flow regulation and adjustment hardware

      ·         Expandable to over 5000 slm with additional molbloc flow elements and control hardware

      ·         Includes traceable calibration for operation in N2 and Air, with corrections for other gases

      ·         Gas supply and test adapters included for 1/4 in tube, 1/4 in NPT and 1/4 in BSP

      ·         Includes advanced functions such as totalize, average, hi/lo, deviation, on-board purge, leak test and tare, available from the front control panel or by RS-232 and IEEE-488 remote interfaces

      A new standard in high end gas flow calibration

      Fluke Calibration revolutionized high end gas flow calibration with the introduction of molbox/ molbloc mass flow standards. molbox/molbloc systems have replaced large, inflexible, error prone volumetric piston provers and bell provers with a compact, easy to use, versatile digital standard. molbox/molbloc systems are the standard of choice for high end calibration labs and mass flow device manufacturers around the world. Improvements offered by molbox/molbloc include:

      ·         True mass flow calibration and traceability— no corrections from volumetric to mass

      ·         Real-time digital mass flow indication, loaded with features—easily automated

      ·         No moving parts—uninterrupted gas flow measurement, no fluctuations from piston stroke

      ·         Flexibility to be positioned upstream or downstream— can calibrate at many line pressures

      ·         Modular components allows future upgrade and expansion

      ·         Very wide range with small footprint—no flow straightening hardware required

       Whether your requirement is manual calibration of a simple variable area flow meter (rotameter) or fully automated calibration of a mass flow controller (MFC), molbox/molbloc systems offer the ideal solution. A molbox RFM with one or more molbloc flow elements can cover a wide range of flow calibration devices with total one-year measurement uncertainty of ± 0.5 % of reading. If your needs change, molbloc flow elements can be added, with models covering flows from 1 sccm to over 5000 slm (175 scfm). If better measurement uncertainty is needed, the same flow elements can be used with molbox1+ to achieve accuracy as good as ± 0.125 % of reading.

      Measurement specifications

      Gas calibration included

      Nitrogen (N2), Air

      Maximum working measurement line pressure

      600 kPa (87 psi) absolute

      Measurement range

      <1sccm to 50 slm, depending on model. Flow ranges depend on test gas. Ranged indicated for N2 and Air.

       

      型號(hào)

      描述

      5141-100

      molbox RFM, molbloc 5E1-L 10 to 100 sccm

      Included:

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E1-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-1K

      molbox RFM, molbloc 5E2-L 100 to 1,000 sccm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-10K

      molbox RFM, molbloc 5E3-L 1 to 10 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E3-L laminar flow element

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-50K

      molbox RFM, molbloc 3E4-L 5 to 50 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 3E4-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-1K

      molbox RFM-M, molbloc 5E2-L 10 to 1,000 sccm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-10K

      molbox RFM-M, molbloc 5E3-L 0.1 to 10 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E3-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-50K

      molbox RFM-M, molbloc 3E4-L 0.5 to 50 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 3E4-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5144-50K

      molbox RFM-M, molblocs 5E2-L and 3E4-L10 sccm to 50 slm

      Included:

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L and 3E4-L laminar flow elements

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      ,
      同類產(chǎn)品
      www.suhaolvshi.cn 遵義molbox RFM Gas Flow Calibrator Kits 版權(quán)所有 備案號(hào): 魯ICP備08106748號(hào)
    12. 
      

      <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
      <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
      <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
        在线免费看毛片,国产精品美女www爽爽爽视频,日逼AⅤ | 三区免费视频,总裁大手伸进内衣揉捏小说,四虎永久影院 | 国产久久久久久久,性生交大片免费看,亚洲午夜剧场 | 欧美一区二区丁香五月天激情,红桃色av,国产精品成人导航欧美另类 | 国产顶级毛片,成熟少妇精油按摩在线观看,国产精品成人无码免费视频小说 |