• 
    

    <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
    <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
    <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
      客戶榮譽(yù)
      kehury
      技術(shù)文章
    1. 張家口molbox RFM Gas Flow Calibrator Kits 5144
    2. 金屬測(cè)厚儀檢測(cè)示值失真預(yù)防措施
    3. RIGOL開關(guān)電源測(cè)試方案
    4. 維氏硬度計(jì)的應(yīng)用和表示方法
    5. 利用數(shù)字示波器完成視頻信號(hào)基本測(cè)量
    6. 噴涂表面與機(jī)加工表面粗糙度的比較
    7. 高精度單片數(shù)據(jù)采集系統(tǒng)MAX1400的原理及應(yīng)用
    8. 智能壓力校驗(yàn)儀的處理方法及故障原因
    9. 熱球式電風(fēng)速計(jì)的原理及使用方法
    10. 射線探傷和超聲探傷的技術(shù)特性簡易比較
    11. 當(dāng)前位置:首頁 > 張家口儀器儀表 > 張家口電子電工 > 張家口計(jì)量校準(zhǔn)
      molbox RFM Gas Flow Calibrator Kits
      型 號(hào):5144
      品 牌:美國FLUKE
      技術(shù)指標(biāo):Maximum working measurement line pressure  600 kPa (87 psi) absolute
      張家口molbox RFM Gas Flow Calibrator Kits-5144-美國FLUKE


      High end gas flow calibration made simple

      Fluke Calibration 5141, 5142 and 5144 molbox RFM gas flow calibrator kits feature molbox RFM and molbloc-L configurations optimized to cover a very wide workload combined with molstic-L and other interconnect hardware needed for a complete calibration system. Simply supply 90 psi of pure N2 or air to the system. An included regulator delivers a stable regulated flow to the molbloc. Downstream of the molbloc, an included metering valve allows you to regulate the mass flow value required for the DUT. It’s that simple; supply 90 psi gas upstream, tare the reading, and adjust the fine metering valve to deliver the desired mass flow rate with an accuracy of ± 0.5 % of reading. Fluke Calibration gas flow calibrator kits eliminate complication, but don’t compromise molbox/molbloc best in class performance.

      ·          Flow ranges cover from 1 sccm to 50 slm

      ·         ± 0.5 % of reading total one-year accuracy

      ·         Measures mass and volume flow with user settable reference pressure and temperature conditions

      ·         Reference standard is upstream of the device under test, eliminating cross contamination and expensive damage to the flow elements

      ·         Integrated gas flow regulation and adjustment hardware

      ·         Expandable to over 5000 slm with additional molbloc flow elements and control hardware

      ·         Includes traceable calibration for operation in N2 and Air, with corrections for other gases

      ·         Gas supply and test adapters included for 1/4 in tube, 1/4 in NPT and 1/4 in BSP

      ·         Includes advanced functions such as totalize, average, hi/lo, deviation, on-board purge, leak test and tare, available from the front control panel or by RS-232 and IEEE-488 remote interfaces

      A new standard in high end gas flow calibration

      Fluke Calibration revolutionized high end gas flow calibration with the introduction of molbox/ molbloc mass flow standards. molbox/molbloc systems have replaced large, inflexible, error prone volumetric piston provers and bell provers with a compact, easy to use, versatile digital standard. molbox/molbloc systems are the standard of choice for high end calibration labs and mass flow device manufacturers around the world. Improvements offered by molbox/molbloc include:

      ·         True mass flow calibration and traceability— no corrections from volumetric to mass

      ·         Real-time digital mass flow indication, loaded with features—easily automated

      ·         No moving parts—uninterrupted gas flow measurement, no fluctuations from piston stroke

      ·         Flexibility to be positioned upstream or downstream— can calibrate at many line pressures

      ·         Modular components allows future upgrade and expansion

      ·         Very wide range with small footprint—no flow straightening hardware required

       Whether your requirement is manual calibration of a simple variable area flow meter (rotameter) or fully automated calibration of a mass flow controller (MFC), molbox/molbloc systems offer the ideal solution. A molbox RFM with one or more molbloc flow elements can cover a wide range of flow calibration devices with total one-year measurement uncertainty of ± 0.5 % of reading. If your needs change, molbloc flow elements can be added, with models covering flows from 1 sccm to over 5000 slm (175 scfm). If better measurement uncertainty is needed, the same flow elements can be used with molbox1+ to achieve accuracy as good as ± 0.125 % of reading.

      Measurement specifications

      Gas calibration included

      Nitrogen (N2), Air

      Maximum working measurement line pressure

      600 kPa (87 psi) absolute

      Measurement range

      <1sccm to 50 slm, depending on model. Flow ranges depend on test gas. Ranged indicated for N2 and Air.

       

      型號(hào)

      描述

      5141-100

      molbox RFM, molbloc 5E1-L 10 to 100 sccm

      Included:

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E1-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-1K

      molbox RFM, molbloc 5E2-L 100 to 1,000 sccm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-10K

      molbox RFM, molbloc 5E3-L 1 to 10 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E3-L laminar flow element

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-50K

      molbox RFM, molbloc 3E4-L 5 to 50 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 3E4-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-1K

      molbox RFM-M, molbloc 5E2-L 10 to 1,000 sccm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-10K

      molbox RFM-M, molbloc 5E3-L 0.1 to 10 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E3-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-50K

      molbox RFM-M, molbloc 3E4-L 0.5 to 50 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 3E4-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5144-50K

      molbox RFM-M, molblocs 5E2-L and 3E4-L10 sccm to 50 slm

      Included:

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L and 3E4-L laminar flow elements

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       


      ,,
      同類產(chǎn)品
      www.suhaolvshi.cn 張家口molbox RFM Gas Flow Calibrator Kits 版權(quán)所有 備案號(hào): 魯ICP備08106748號(hào)
    12. 
      

      <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
      <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
      <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
        成年人黄色网址,免费看黄色片视频,李信和阿里拔萝卜是什么意思 | 日韩在线播放视频,天天操天天操天天操天天,国产青青在线观看 | 亚洲专区免费,美女一级全黄大片,日韩精品一区二区三区四区五区 | 91成人 在线观看喷潮,国产棈品久久久久久久久久免费看,欧美在线一区二区三区 | 国产剧情自拍,麻豆网神马久久人鬼片,懂色无码中字幕一区 |