      紅外熱像儀
      型 號(hào):FLIR A310 ex
      品 牌:美國(guó)FLIR
      技術(shù)指標(biāo):范圍:–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
      黔南紅外熱像儀-FLIR A310 ex-美國(guó)FLIR

      Fully compliant with ATEX regulations

      Use the power of thermal imaging in hazardous locations.

      Explosive atmospheres need to be protected from ignition sources by selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations.

      FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Process monitoring, quality control and fire detection in potentially explosive locations are typical applications for the A310 ex.



      FLIR A310 ex Thermal Camera Features

      A310ex schema
      1. Heater
      2. Sensors for temperature, air humidity, voltage & pressure
      3. Power supply: 24V DC
      4. 2 SFP ports for fiber optic, 100 Base-FX or copper ethernet
      5. ATEX compliant housing

      Learn more about the FLIR A310, the thermal imaging camera inside FLIR A310 ex.


      Flame-Proof Enclosure “d”

      Prevents any explosion transmission from the inside of the enclosure to the outside.


      For use in harsh environments: IP67

      The FLIR A310 ex is IP67 rated. Ideal to install in dusty environments.


      Integrated controller

      The integrated controller features several digital I/O channels and sensors for temperature, humidity and pressure. Among other functions, the I/O channels enable the user to switch on/off the camera and the heater via remote control. The access is accomplished through an integrated web interface or Modbus TCP/IP.


      Flexible integration

      The integrated controller is equipped with 2 fiber optic and 2 Ethernet parts. This enables a flexible network integration in star or ring topologies.


      Heater

      FLIR A310 ex comes with a heater which effectively prevents fogging and freezing of the protection window.


      Plug and play installation

      FLIR A310 ex is lightweight and the entire system is delivered ready for use.


      Verification Certificate ZELM 12 ATEX 0485 X

      The FLIR A310 ex is ATEX certified. It can be installed in classification zones 1, 2, 21, 22.

      The certification comprises the whole system which includes the enclosure as well as all components inside, such as the thermal imaging camera, heater and integrated controller.

      Learn more about the FLIR A310, the thermal imaging camera inside FLIR A310 ex.



      FLIR A310 ex Technical Specifications

      General Data
      Ambient temperature range for operation –20°C to +40°C (-4°F to 104°F)
      Protection class IP67
      Weight 6.7 kg (without camera and lens)
      Empty volume 5.06 l
      External dimensions (without sun shield) D = 170 mm, L = 408 mm
      Housing material / Surface Nickel-plated aluminium / Powder coated
      Protection window Germanium, double-sided AR Coated, externally with additional hard-carbon layer
      Maximum power of the additional heater 16 W
      Operating voltage 24 V DC
      Maximum electric connection power 60 W
      Power cable / Power cable configuration Helukabel 37264 / Pigtail
      Length of power cable 4 m (13 ft.)
      Integrated controller 4-port switch with 2 × fiber-optic LC 100Base-FX or 2 × RJ45(10/100) up-links, ring-topology support for reduced cabling effort, 2 × internal temperature sensors, air humidity and pressure sensor, digital output module controllable via Modbus TCP/IP or web interface to enable turning the heater on/off
      Ethernet medium Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125 OM2
      Length of Ethernet cable 4 m (13 ft.)
      Ethernet, configuration Pigtail with FC-connector
      Explosion protection-specific data
      For use in EX zone 1, 2, 21, and 22
      Ignition protection category Flame-proof enclosure “d”
      Maximum surface temperature (according to temperature class T6) Maximum 85°C
      ATEX certification (version -AXC) EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db
      Verification certificate ZELM 12 ATEX 0485 X
      Imaging and optical data
      IR resolution 320 × 240 pixels
      Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
      Field of view (FOV) / Focal length 25° × 18.8° with 18 mm (0.7 in.) lens or 45° × 33.8° with 9.66 mm (0.38 in.) lens
      Minimum focus distance 0.4 m (1.31 ft.)
      Spatial resolution (IFOV) 1.36 mrad with 25° lens or 2.59 mrad with 45° lens
      Lens identification Automatic
      F-number 1.3
      Image frequency 30 Hz
      Focus Automatic or manual (built in motor)
      Zoom 1–8× continuous, digital, interpolating zooming on images
      Detector data
      Detector type Focal Plane Array (FPA), uncooled microbolometer
      Spectral range 7.5–13 μm
      Detector pitch 25 μm
      Detector time constant Typical 12 ms
      Measurement
      Object temperature range –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
      Accuracy ±2°C (±3.6°F) or ±2% of reading
      Measurement analysis
      Spotmeter 10
      Area 10 boxes with max./min./average/position
      Isotherm 1 with above/below/interval
      Measurement option Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
      Difference temperature Delta temperature between measurement functions or reference temperature
      Reference temperature Manually set or captured from any measurement function
      Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
      Optics transmission correction Automatic, based on signals from internal sensors
      Emissivity correction Variable from 0.01 to 1.0
      Reflected apparent temperature correction Automatic, based on input of reflected temperature
      External optics/windows correction Automatic, based on input of optics/window transmission and temperature
      Measurement corrections Global and individual object parameters
      Alarm
      Alarm functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
      Alarm output Digital Out, log, store image, file sending (ftp), email (SMTP), notification
      Set-up
      Color palettes Color palettes (BW, BW inv, Iron, Rain)
      Set-up commands Date/time, Temperature°C/°F
      Storage of images
      Storage media Built-in memory for image storage
      File formats Standard JPEG, 16-bit measurement data included
      Ethernet
      Ethernet Control, result and image
      Ethernet, type / standard 100 Mbps / IEEE 802.3
      Ethernet, configuration Pigtail with FC-connector (fiber)
      Ethernet, communication TCP/IP socket-based FLIR proprietary
      Ethernet, video streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
      Ethernet, image streaming 16-bit 320 × 240 pixels @ 7-8 Hz - Radiometric
      Ethernet, protocols Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
      Shipping information
      Infrared camera with lens, in explosion-proof housing, cardboard box, Printed documentation, User documentation CD-ROM, Utility CD-ROM


      ,,
      同類產(chǎn)品
      www.suhaolvshi.cn 黔南紅外熱像儀 版權(quán)所有 備案號(hào): 魯ICP備08106748號(hào)
    12. 
      

      <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
      <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
      <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
        黄色电影特黄一级片,国产专区在线播放,日本一二三在线播放 | 亚洲一区无码,欧美办公室灰丝袜丝交,久久伊人免费视频 | 综合激情网,精品福利一区,美女靠逼网站 | 啊啊啊啊啊靠逼,粗长灌满h双龙h双性男男动漫,日韩在线一区二区红桃视频在线观看 | 美日韩黄片,看老头玩娇妻刺激,大香蕉伊人影院 |