      Full Immersion PRT
      型 號(hào):5606
      品 牌:美國(guó)FLUKE
      技術(shù)指標(biāo):Temperature range –200 °C to 160 °C
      杭州Full Immersion PRT-5606-美國(guó)FLUKE

      PRTs for laboratory freezers, autoclaves, and furnaces

      ·         5606: -200 °C to 160 °C

      ·         Calibration accuracy of ± 0.05 °C

      ·         Transition junction and lead wires can withstand full PRT temperature range

      ·         Unique probe seal of 5606 prevents ingress of moisture

      ·         Calibration not included; NVLAP-accredited calibration optional

      The 5606 Full Immersion PRTs are designed to perform in extreme environments where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe. (“Immersion” in this case simply means exposure to temperatures other than ambient and does not necessarily refer to the medium to which the PRT and its components are subjected.)

      Applications where “full immersion” of probe, transition junction, and lead wire is required can include calibration or validation of sensors used in laboratory or bio freezers, walk-in refrigerators, autoclaves, ovens, stability test chambers, furnaces or incubators. Other applications might include IQ/ OQ/PQ qualification procedures, temperature mapping, or data logging in temperature controlled spaces or environmental chambers.

      The 5606 is just two inches (50 mm) in length with a sheath diameter of 1/8 inch (3.1 mm). Since it can be fully immersed over its entire temperature range, you don’t have to worry about calculating minimum immersion depth— immerse the entire probe, transition junction, and lead wires, in either non-corrosive liquids or dry mediums ranging from –200 °C to 160 °C.

      The 100 Ω precision sensing element (alpha = 0.00385) is specially constructed to prevent the ingress of moisture while achieving calibration accuracies as good as ± 0.05 °C. You get both accuracy and flexibility built into a small, durable package.

      The lead wires of the 5606 are made of single-conductor enameled copper wire which prevents moisture from wicking to the sensing element as it would if a more common, stranded lead wire were used. The diameter of the lead wire is no greater than 0.2 mm, making it easy to run lead wires through a freezer door to your readout or transmitter with effectively zero energy loss. The 5606 has been proven in common heat transfer fluids such as silicone oil, mineral oil, ethanol, and even liquid nitrogen with no degradation of the transition junction seal or lead wire insulation.

      If you need longer lead wire than the standard length, call one of our Application Specialists today for a free quote. They can also help you determine which readout and probe termination are best suited for your application or help you select the right calibration for your probe.

      General Specifications

      Temperature range

       –200 °C to 160 °C

      Nominal resistance at 0.01 °C

      100Ω± 0.1Ω

      Temperature coefficient

      0.00385Ω/Ω/°C

      Accuracy[1]

       ± 0.04 °C at 0.01 °C

       ± 0.06 °C at 160 °C

      Short-term repeatability[2]

       ± 0.03 °C at 0.01 °C

       ± 0.04 °C at 160 °C

      Drift[3]

       ± 0.03 °C at 0.01 °C

       ± 0.04 °C at 160 °C

      Hysteresis

      ± 0.015 °C

      Sheath length

       50 mm ± 5 mm

       (2 in ± 0.2 in)

      Sheath diameter

      3.1 mm ± 0.1 mm (1/8 in ± 0.004 in)

      Sheath material

       316 SST

      Transition junction temperature range[4]

       –200 °C to 160 °C

      Sensor length

      30 mm ± 3mm (1.2 in ±0.1 in)

      Sensor location

      3 mm ± 1 mm from tip (1.2 in ± 0.04 in)

      Minimum insulation resistance

       20 MΩat 23 °C

      Minimum immersion length

      Full immersion

      Maximum immersion depth in liquid medium

      Full immersion

      Response time[5]

      12 seconds typical

      Self heating (in 0 °C bath)

       ± 0.003 °C

      Lead-wire cable type

       Enameled copper wire

      Lead-wire length

      2.4 meters (8 ft)

      Lead-wire temperature range

       160 °C

      Calibration

      Calibration not included. NVLAP accredited calibration available. See ordering information.

      [1] Includes calibration and 100 hr drift (k = 2).
      [2] Three thermal cycles from min to max temp, includes hysteresis, 95 % confidence (k = 2).
      [3] After 100 hours at max temp, 95 % confidence (k = 2).
      [4] Temperatures outside this range will cause irreparable damage.
      [5] Per ASTM E 644.

      Calibration uncertainty

       

      5606

      Temperature

      1924 Calibration Uncertainty†

      Tolerance w/out Calibration‡

      -197 °C

      0.03 °C

      0.4 °C

      -38 °C

      0.03 °C

      0.2 °C

      0 °C

      0.03 °C

      0.1 °C

      100 °C

      0.045 °C

      0.3 °C

      157 °C

      0.05 °C

      0.4 °C

       

       

       

      † Lab code 200348-0
      ‡ Each PRT includes a certificate with a measured R0 value.
      An uncalibrated 5606 meets ASTM E 1137 Grade A Classification of Tolerances. Use the coefficients below to achieve the tolerances listed in the “No Calibration” column or calculate the Grade A tolerance using the following formula: Grade A = ± [0.13 + 0.0017|t|]°C where: |t| = value of temperature (°C) without regard to sign. See ASTM E 1137. 
      R0: Enter the R0 value provided 
      A: 3.9083 x 10–3
      B: –5.775 x 10–7
      C: –4.183 x 10–12

       

      型號(hào)

      描述

      5606-50-X

      探頭,浸入式PRT,,50 mm,,-200到160°C

      † X =終止。指定“A”(適用于914X的INFO-CON)、“B”(裸線)、“D”(適用于Tweener溫度計(jì)的5針DIN)、“G”(金針)、“I”(適用于1521或1522的INFO-CON)、“J”(香蕉插頭)、“L”(微型平接線片)、“M”(微型香蕉插頭)、“P”(適用于1523或1524的INFO-CON)或“S”(平接線片)。

      配件

      描述

      1924-4-10

      PRT校準(zhǔn),

      1930-4-10

      系統(tǒng)對(duì)比校準(zhǔn),-200至157°

      通用配件:


      配件

      描述

      2603

      小探頭提行箱

       

      同類產(chǎn)品
      www.suhaolvshi.cn 杭州Full Immersion PRT 版權(quán)所有 備案號(hào): 魯ICP備08106748號(hào)
    12. 
      

      <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
      <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
      <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
        国产欧美日韩,岳的两片蚌肉缓缓张开乡村欲爱,91极品蝌蚪 | 日本黄色免费在线观看,人人干人人视频,jizzjizzjizzjizz | 三级在线观看,8050午夜一级少妇电影院,97骚逼 | 午夜国产av,激情五月色综合国产精品,超碰3 | 肏屄视频欧美,免费淫片aa直播app,中国美女操逼的视频 |