• 
    

    <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
    <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
    <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
      客戶榮譽(yù)
      kehury
      技術(shù)文章
    1. 定西molbox RFM Gas Flow Calibrator Kits 5141
    2. 毫歐姆級(jí)電阻測(cè)量電路設(shè)計(jì)
    3. 常用維氏、布氏、洛氏硬度的換算表
    4. 激光測(cè)距儀新方法,新應(yīng)用
    5. 測(cè)定純水pH值的影響因素
    6. 一氧化碳傳感器主要組成系統(tǒng)
    7. 場(chǎng)強(qiáng)儀測(cè)量單位換算表
    8. 理解Fluke 43B的記錄功能
    9. 維氏硬度計(jì)選型注意事項(xiàng)
    10. 照度計(jì)的基本原理知識(shí)
    11. 當(dāng)前位置:首頁 > 定西儀器儀表 > 定西電子電工 > 定西計(jì)量校準(zhǔn)
      molbox RFM Gas Flow Calibrator Kits
      型 號(hào):5141
      品 牌:美國(guó)FLUKE
      技術(shù)指標(biāo):Maximum working measurement line pressure  600 kPa (87 psi) absolute
      定西molbox RFM Gas Flow Calibrator Kits-5141-美國(guó)FLUKE

      High end gas flow calibration made simple

      Fluke Calibration 5141, 5142 and 5144 molbox RFM gas flow calibrator kits feature molbox RFM and molbloc-L configurations optimized to cover a very wide workload combined with molstic-L and other interconnect hardware needed for a complete calibration system. Simply supply 90 psi of pure N2 or air to the system. An included regulator delivers a stable regulated flow to the molbloc. Downstream of the molbloc, an included metering valve allows you to regulate the mass flow value required for the DUT. It’s that simple; supply 90 psi gas upstream, tare the reading, and adjust the fine metering valve to deliver the desired mass flow rate with an accuracy of ± 0.5 % of reading. Fluke Calibration gas flow calibrator kits eliminate complication, but don’t compromise molbox/molbloc best in class performance.

      ·          Flow ranges cover from 1 sccm to 50 slm

      ·         ± 0.5 % of reading total one-year accuracy

      ·         Measures mass and volume flow with user settable reference pressure and temperature conditions

      ·         Reference standard is upstream of the device under test, eliminating cross contamination and expensive damage to the flow elements

      ·         Integrated gas flow regulation and adjustment hardware

      ·         Expandable to over 5000 slm with additional molbloc flow elements and control hardware

      ·         Includes traceable calibration for operation in N2 and Air, with corrections for other gases

      ·         Gas supply and test adapters included for 1/4 in tube, 1/4 in NPT and 1/4 in BSP

      ·         Includes advanced functions such as totalize, average, hi/lo, deviation, on-board purge, leak test and tare, available from the front control panel or by RS-232 and IEEE-488 remote interfaces

      A new standard in high end gas flow calibration

      Fluke Calibration revolutionized high end gas flow calibration with the introduction of molbox/ molbloc mass flow standards. molbox/molbloc systems have replaced large, inflexible, error prone volumetric piston provers and bell provers with a compact, easy to use, versatile digital standard. molbox/molbloc systems are the standard of choice for high end calibration labs and mass flow device manufacturers around the world. Improvements offered by molbox/molbloc include:

      ·         True mass flow calibration and traceability— no corrections from volumetric to mass

      ·         Real-time digital mass flow indication, loaded with features—easily automated

      ·         No moving parts—uninterrupted gas flow measurement, no fluctuations from piston stroke

      ·         Flexibility to be positioned upstream or downstream— can calibrate at many line pressures

      ·         Modular components allows future upgrade and expansion

      ·         Very wide range with small footprint—no flow straightening hardware required

       Whether your requirement is manual calibration of a simple variable area flow meter (rotameter) or fully automated calibration of a mass flow controller (MFC), molbox/molbloc systems offer the ideal solution. A molbox RFM with one or more molbloc flow elements can cover a wide range of flow calibration devices with total one-year measurement uncertainty of ± 0.5 % of reading. If your needs change, molbloc flow elements can be added, with models covering flows from 1 sccm to over 5000 slm (175 scfm). If better measurement uncertainty is needed, the same flow elements can be used with molbox1+ to achieve accuracy as good as ± 0.125 % of reading.

      Measurement specifications

      Gas calibration included

      Nitrogen (N2), Air

      Maximum working measurement line pressure

      600 kPa (87 psi) absolute

      Measurement range

      <1sccm to 50 slm, depending on model. Flow ranges depend on test gas. Ranged indicated for N2 and Air.

       

      型號(hào)

      描述

      5141-100

      molbox RFM, molbloc 5E1-L 10 to 100 sccm

      Included:

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E1-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-1K

      molbox RFM, molbloc 5E2-L 100 to 1,000 sccm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-10K

      molbox RFM, molbloc 5E3-L 1 to 10 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E3-L laminar flow element

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5141-50K

      molbox RFM, molbloc 3E4-L 5 to 50 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 3E4-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-1K

      molbox RFM-M, molbloc 5E2-L 10 to 1,000 sccm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-10K

      molbox RFM-M, molbloc 5E3-L 0.1 to 10 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E3-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5142-50K

      molbox RFM-M, molbloc 3E4-L 0.5 to 50 slm

      Included: 

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 3E4-L laminar flow element 

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      5144-50K

      molbox RFM-M, molblocs 5E2-L and 3E4-L10 sccm to 50 slm

      Included:

      ·        molbox RFM (5141 kits) or molbox RFM-M (5142 and 5144 kits) reference flow monitor with quick connect molbloc pressure lines, molbloc communication cable, line cord and user manual

      ·        molbloc 5E2-L and 3E4-L laminar flow elements

      ·        molstic-L mounting system, with fine pressure regulator and an isolation valve and precise flow metering valve for each molbloc-L

      ·        Tubing and adaptors to connect gas supply and device under test, including 1/4 in tube fitting, 1/4 in NPT female, 1/4 in NPT male, 1/8 in NPT male and 1/4 in BSP male

       

      ,,
      同類產(chǎn)品
      www.suhaolvshi.cn 定西molbox RFM Gas Flow Calibrator Kits 版權(quán)所有 備案號(hào): 魯ICP備08106748號(hào)
    12. 
      

      <dl id="nc2mn"><sup id="nc2mn"><ins id="nc2mn"></ins></sup></dl>
      <u id="nc2mn"><menuitem id="nc2mn"></menuitem></u>
      <label id="nc2mn"><xmp id="nc2mn"><ins id="nc2mn"></ins>
        高清无码免费看,美女被草哭,操操操影院 | 日韩福利在线,日本护士高潮水真多,淫秽视频免费看 | 最新中文字幕在线观看,美女脱裤子让男人捅,一区二区三区免费精品 | 日韩免费一区二区,91精品国产91综合久久蜜臀,青娱乐极品精品 | 啪网站,国产午夜精品久久久久久久久久,福瑞控18禁无遮挡▓网站入口 |